RC1
Noise Suppressor |
-
The RC1 Noise
Suppressor is designed to eliminate noise caused by switching
of inductive loads. Pump motors, solenoid valves, motor
contactors, and other inductive loads cause high voltage
spikes on the AC line when they are switched on or off. The
RC1 eliminates these spikes at the source, preventing them
from affecting sensitive equipment.
|
 |
Connect the RC1 directly
across the hot and neutral wires of the load, as close as
possible to the coil or motor winding. This will allow the RC1
to filter the inductive noise before it travels to other
devices. For best results, install one RC1 on each suction
motor, solenoid valve, and motor contactor at the site. The
RC1 is constructed as small as possible to allow it to be
mounted inside the junction box of the dispenser.
|
 |
|
SPECIFICATIONS:
|
Input (Black Wires) |
|
Voltage: |
250 Vmax |
|
Internal
Capacitance: |
0.1uF |
|
Internal
Resistance: |
68
Ω |
|
Dimensions: |
1.0 x 0.6 x
0.4 Inches |
|
Wire Length: |
5 Inches |
|
|
MODEL NUMBERS AND LIST PRICING:
|
Model
Number: |
Description: |
List Price: |
|
RC1 |
RC1 Noise
Suppressor |
$19.95 |
|
|
ADDITIONAL RC1 DOCUMENTATION: (These files are in PDF Format.)

RC1 Information Page
RC1 Installation Instructions
|
 |